The Series 240 Manifold is designed specifically to regulate and monitor vaporized gas from cryogenic cylinders. The Series 240 Manifold prevents downtime by automatically switching over when the primary cylinder bank is depleted. A green light indicates the primary cylinder service bank is functioning and the reserve cylinder bank is ready for service. A red light signals that the system has changed over and one or both banks are depleted. The user resets the primary bank by turning the lever.
• Connects to remote alarm systems.
Up to 3 amps 30 volts (DC) or 2 amps 250 volts
(AC) Visual remote alarm is standard.
Audio/Visual alarm optional.
• Electrical - 115 volts (AC).
• Maximum inlet pressure 350 PSIG
• Maximum flow rate
240............................ 750 SCFH
240HP....................... 800 SCFH
• Adjustable line regulator
240.......................... 40-85 PSIG
240HP.................... 40-180 PSIG