The QC+ Point of Operation Panel contains purifier cartridges that can be quickly changed. The cartridges are removed from the panel without interruption of gas flow to the system, drastically minimizing costly instrument downtime.
Filter cartridges are of all metal or glass construction, eliminating infusion and resultant signal noise associated with filters constructed from plastics. Cartridges are quickly installed via a simple knurled retaining nut. No wrenches are needed! As many as four cartridges can be replaced in a matter of seconds, and because there is low dead volume, a minimal amount of gas system purge is required after installation.
Each QC+ filter head is equipped with an internal flow valve. This valve serves two functions. In the “down” position, gas is passed through adsorbent filter cartridges for purification. In the “up” position, the gas is diverted through the filter head. With the valve up, the filter can then be easily replaced with a fresh cartridge. But, because the gas continues to flow through the bypass valve, the need to shut down instruments is eliminated while the filter cartridges are removed. QC+ is the only GC purification system with this revolutionary “flow through/bypass” feature.
The QC+ system has a unique D-shaped cartridge top that is self-aligning into the matching slotted filter head, assuring trouble-free installations. As many as four cartridges can be replaced in a matter of seconds without exposing downstream plumbing to atmospheric contaminants.
QC+ systems are available in single-head kits or 2-,3- and 4-head panel configurations, available exclusively with 1/8 in. Swagelok fittings. QC+ panels can be wall mounted or used “freestanding.” Oxygen, water, hydrocarbons and other organics are reduced to low part per billion levels.
|
|
| Replacement
Cartridges |
High Capacity Oxygen
The GC-1 oxygen cartridge is an all metal assembly that contains a highly active metal catalyst, supported on an alumina silicate substrate. Oxygen removal efficiency to less than 15 ppb.
P/N: 4302695; Capacity: 396 mg |
|
|
High Capacity Moisture
The GC-2 moisture cartridge is an all metal assembly that contains 13X molecular sieve, 16-20 mesh sphere size. Water removal efficiency to less than 9 ppb.
P/N: 4302696; Capacity: 15 g |
|
|
Indicating
Moisture
The GC-2-1 indicating moisture cartridge is a glass assembly that contains a combination of 5A molecular sieve and indicating Drierite. This cartridge provides a visual indicator of adsorbent saturation. Water removal efficiency to less than 9ppb.
P/N: 4302697; Capacity: 7 g |
|
|
Hydrocarbon
The GC-3 hydrocarbon cartridge is an all metal assembly that contains a high surface area and coconut shell-based, activated carbon medium. Efficiencies to low ppb levels for C2 and heavier compounds. Hydrocarbon removal efficiency to less than 30 ppb.
P/N: 4302698; Capacity: 8 g |
|
|
Indicating Oxygen
The GC-4 indicating oxygen cartridge is constructed from glass. It contains a manganese oxide adsorbent that experiences a dramatic and progressive color change during adsorption. Oxygen removal efficiency to less than 2 ppb.
P/N: 4302699; Capacity: 40 mg |
|
|
|
1a |
1b |
|
Figures 1a and 1b. The “plus” valve (a) features a closed gas path when changing cartridges. When placed in the down position (b), the “plus” valve shifts gas through the cartridge. |
|
|
 |
|
|
|
| PART
NO. |
DESCRIPTION |
FITTING
(in.) |
1-HEAD
4302766
4302764
2-head
4302770
4302767
4302768
4302769
3-HEAD
4302781
4302780
4-HEAD
4302779 |
High Capacity Oxygen
Indicating Oxygen
High Cap Indicating Oxy.
Moisture, Hydrocarbon
Indicating Moisture & Hydrocarbon
Moisture & Indicating Moisture
Oxygen, Moisture, Hydrocarbon
Moisture, Oxygen, Ind. Oxygen
02, Indicating 02, HC, H20
|
1/8
1/8
1/8
1/8
1/8
1/8
1/8
1/8
1/8
|
|
|
|
|
|
|
|
|
|
| Replacement
Cartridges |
| PART
NO. |
DESCRIPTION |
4302695
4302696
4302697
4302698
4302699
4302765
|
High Capacity Oxygen
High Capacity Moisture
Indicating Moisture
Hydrocarbon
Indicating Oxygen
Replacement O-Ring Set |
|
|
|
|
|
|
|